Users can set and select the following through keystrokes and displays18. In one of these functions, function parameters can be set and saved, and time parameters can be set to a minimum.0.1. The second is adjustable and the accuracy is better than 0.0. One second, about the specific set-up operation instructions, can be obtained from the seller.
Reminder:
1. Function 1-8 is self-starting when it is powered on. Function 9-18 needs high (low) level pulse signal to trigger start (high (low) level duration is not shorter than2Function 9 is self-locking mode, Function 10 is level control mode.
2. The X interface mentioned in the following text can be any of the X1-X4 interfaces.
Function 1:
Power Delay Absorption: Delay from Power UpT1After time, the relay sucks.T1stay0.1Seconds - 270 hoursAdjustable between the X interface at any time to a high (low) level pulse signal, this function reset and restart operation;
Function 2:
Power-on delay disconnection: relay suction and suction when power-onT1After time, the relay is disconnected.T1stay0.1Seconds - 270 hoursAdjustable between the X interface at any time to a high (low) level pulse signal, this function reset and restart operation;
Function 3:
Timing suction and re-disconnection: the relay is disconnected when the power is on, the relay is sucked when the disconnection time T1 arrives, and the relay is disconnected when the suction time T2 arrives.T1And T2 in0.1 seconds - 270 hoursAdjustable between the X interface at any time to a high (low) level pulse signal, this function reset and restart operation;
Function 4:
Timing disconnection and re-suction: relay suction when power on, relay disconnection when suction time T1 arrives, and relay suction when disconnection time T2 arrives.T1And T2 in0.1Seconds - 270 hoursAdjustable between the X interface at any time to a high (low) level pulse signal, this function reset and restart operation;
Function 5:
Infinite cycle mode 1: When power on, the relay is disconnected, the disconnection time T1 arrives and the relay is sucked; when the suction time T2 arrives, the relay is disconnected, and then the above state is repeated.T1And T2 in0.1Seconds - 270 hoursAdjustable between the X interface at any time to a high (low) level pulse signal, this function reset and restart operation;
Function 6:
Infinite cycle mode 2: When power on, the relay immediately sucks in, the suction time T1 arrives and the relay disconnects; when the disconnection time T2 arrives, the relay sucks in, and then repeats the above state., T1And T2 in0.1Seconds - 270 hoursIt can adjust between them and give X interface a high /(low) level pulse signal at any time. This function is reset and restarted.
Function 7:
FINITE CYCLE MODE 1: Relay is disconnected when powered on, and the disconnection time T1 reaches the relay suction; the relay is disconnected when the suction time T2 arrives, and then repeats.NXMore than two movements,T1And T2 in0.1Seconds -9999 secondsThe number of cycles NX can be adjusted between 1 and 9999. A high (low) level pulse signal is given to X interface at any time. This function is reset and restarted.
Function 8:
FINITE CYCLE TIME MODE 2: Relay suction when power on, relay disconnection when suction time T1 arrives, relay suction when disconnection time T2 arrives, and then repeat.NXMore than two movements,T1And T2 in0.1Seconds -9999 secondsThe number of cycles NX can be adjusted between 1 and 9999. A high (low) level pulse signal is given to X interface at any time. This function is reset and restarted.
Function 9:
Self-locking relay mode: to relay X interface a high (low) level pulse signal, relay suction, and then to a high (low) level pulse signal relay disconnected.
Function 10:
Level trigger relay mode (including delayed disconnection function): When power on, the relay is disconnected, giving X interface a high (low) level signal, the relay immediately sucks in, after X port signal disappears, the relay still sucks in, when the suction time T1 arrives, the relay is disconnected, at this time.T1stay0Seconds - 270 hoursAdjustable between.
Note: In this function, if T1 is set to 0 seconds, it becomes: X port has high (low) level signal relay to absorb, no signal will be immediately disconnected.
Function 11:
Trigger timing suction: when power on, the relay is disconnected, giving X interface a high (low) level pulse signal, delayT1Time relay suction,T1stay0.1Seconds - 270 hoursBetween adjustable, repeat to X interface a high (low) level pulse signal, repeat more than one function;
Function 12:
Trigger timing disconnection: when power on, the relay disconnects, giving X interface a high (low) level pulse signal, relay suction, suctionT1The time relay is disconnected.T1stay0.1Seconds - 270 hoursBetween adjustable, repeat to X interface a high (low) level pulse signal, repeat more than one function;
Function 13:
Trigger timing suction and re-disconnection: when power on, the relay is disconnected, giving X interface a high (low) level pulse signal, and the relay is sucked after the disconnection time T1 arrives; when the suction time T2 arrives, the relay is disconnected.T1And T2 in0.1 seconds - 270 hoursBetween adjustable, repeat to X interface a high (low) level pulse signal, repeat more than one function;
Function 14:
Trigger timing disconnection and reabsorption: when power on, the relay is disconnected, giving X interface a high (low) level pulse signal, the relay is sucked, the relay is disconnected after the suction time T1 arrives, and the relay is sucked after the disconnection time T2 arrives.T1And T2 in0.1Seconds - 270 hoursBetween adjustable, repeat to X interface a high (low) level pulse signal, repeat more than one function;
Function 15:
Infinite cycle mode 1: When power on, the relay is disconnected, giving X interface a high (low) level pulse signal, delay time T1 arrives after the relay is sucked; suction time T2 arrives after the relay is disconnected, and then repeat the above actions.T1And T2 in0.1Seconds - 270 hoursThe above functions can be restarted by repeating a high (low) level pulse signal to X interface.
Function 16:
Infinite cycle mode 2: When power on, the relay is disconnected, giving X interface a high (low) level pulse signal, the relay is sucked in, and the relay is disconnected after the suction time T1 arrives; when the disconnection time T2 arrives, the relay is sucked in, and then repeats the above actions.,delayT1And T2 in0.1Seconds - 270 hoursThe above functions can be restarted by repeating a high (low) level pulse signal to X interface.
Function 17:
Limited cycle timing mode 1: When power on, the relay is disconnected, giving X interface a high (low) level pulse signal, the disconnection time T1 arrives and the relay is sucked; when the suction time T2 arrives, the relay is disconnected, and then repeats the action of NX more than once.T1And T2 in0.1Seconds -9999 secondsThe number of cycles NX can be adjusted between 1 and 9999, and the above functions can be restarted by repeating a high (low) level pulse signal to X interface.
Function 18:
FINITE CYCLE TIME MODE 2: When power on, the relay is disconnected and a high (low) level pulse signal is given to X interface. The relay is immediately sucked in, and the relay is disconnected after the suction time T1 arrives. When the disconnection time T2 arrives, the relay sucks in, and then repeats the action of NX times or more, at this time.T1And T2 in0.1Seconds -9999 secondsThe number of cycles NX can be adjusted between 1 and 9999, and the above functions can be restarted by repeating a high (low) level pulse signal to X interface.